This procedure is written for ATH processing, with focus on dust explosion risk (ATEX), static control, cross-contamination prevention, low‑iron grade protection and lockout/tagout (LOTO). It applies to ACM air classifier mill: grinding rotor, pins, classifier wheel, housing, labyrinth seal, internal air channels, return duct and coarse recycle chute. This guide follows ath-mill.com safety and maintenance standards.
1. Pre-cleaning mandatory safety steps (non-negotiable)
- Stop the system and perform LOTO (Lockout / Tagout)
- Stop feeder, mill, classifier, ID fan, all auxiliary blowers and conveyors.
- Isolate electrical power, compressed air and hydraulic supplies; apply lockout tags.
- Wait for cool-down: allow internal temperature to drop below 40 °C. ATH residue trapped inside can retain heat; hot powder creates re‑agglomeration and ignition risk.
- Depressurize and purge residual dust cloud
- Run the fan briefly (only when mill access doors are closed) to evacuate suspended dust, then re-LOTO before opening.
- Do NOT open inspection hatches while the fan is running.
- Check atmosphere (ATEX requirement)
If the plant is ATEX-classified: monitor oxygen and dust concentration. Eliminate any flammable solvent vapors from prior surface‑treated ATH batches. - Personal protective equipment (PPE)
- Anti-static conductive dust suit, conductive safety shoes, safety goggles, N95/P100 dust respirator, nitrile gloves.
- Normal static-prone plastic clothing is forbidden; static discharge can ignite ATH dust clouds.
- Ground and bond all cleaning tools
- Conductive brushes, conductive vacuum wands must be bonded to the mill’s equipotential grounding point before use.
- Non-conductive plastic brushes create static sparks and are not permitted inside the mill.
2. Approved cleaning methods for ATH ACM mill
Method A: Conductive industrial vacuum cleaning (preferred for low‑iron, high‑whiteness ATH)
This is the best method to avoid re-suspending large dust clouds.
- Use only ATEX-certified conductive dust vacuum, with antistatic hose and filter.
- Start from the top (classifier housing, upper duct) and work down to rotor, grinding chamber, recycle chute.
- Keep the vacuum nozzle in contact with the component surface at all times to maintain bonding.
- For thin cake on classifier wheel blades: use soft conductive bristle brush together with vacuum extraction.
Advantage: minimal dust escape, lowest risk of scratching ceramic/alloy coated wear parts and introducing iron contamination.
Limitation: thick, hard-caked ATH cannot be removed by vacuum alone.
Method B: Low-pressure dry compressed air purge (only with local extraction)
- Air pressure ≤ 0.2 MPa (2 bar); high-pressure air blows dust clouds and creates explosion hazard.
- Must have an extraction vacuum running at the same time to capture dislodged dust.
- Use an antistatic air nozzle, bonded to the mill.
- Never blow powder toward inspection openings or out into the workshop.
- Do NOT use oil-lubricated compressed air — oil contaminates ATH and ruins whiteness.
Best for loose powder residue on air channels, labyrinth seal gaps and coarse return passages.
Method C: Gentle mechanical scraping (for hard, baked-on ATH cake)
- Use non-sparking, non-ferrous scrapers (brass, nylon conductive). Steel scrapers are forbidden: they scratch hardfaced surfaces and shed metal, increasing iron content in subsequent ATH batches.
- Scrape slowly, chip off cake in small pieces while vacuuming continuously.
- Special attention: classifier wheel blades. Avoid bending blade edges or damaging the wheel balance; a deformed wheel will cause vibration and PSD fluctuation.
❌ Methods that are prohibited
- High-pressure air (>0.2 MPa) without extraction
- Water washing inside the mill (unless the mill is fully designed for wet wash; residual moisture causes severe ATH agglomeration and blockage on next startup)
- Steel wire brushes, steel scrapers
- Compressed air blow-down without dust capture
- Cleaning while the mill is hot
- Using ordinary household vacuum cleaners (non-conductive, non-ATEX)
3. Component-by-component cleaning sequence
Follow this order to prevent dislodged cake from falling into already cleaned zones:
- Upper classifier housing, top cover, outlet transition duct
- Classifier wheel and blade gaps, labyrinth seal assembly
The seal purge air holes are easy to block; clear them carefully. Blocked purge air is a major cause of PSD drift.
- Grinding chamber inner wall
- Rotor and grinding pins
- Inspect pins while cleaning; mark bent, grooved or heavily worn pins for replacement.
- Coarse recycle chute and return passages
- Lower inlet and feeder connection spool
Critical note: After cleaning the classifier wheel, inspect for uneven cake residue. If residue is uneven, the wheel will be out of balance and trigger vibration immediately after startup.
4. Cross-contamination control (critical if switching ATH grades)
- If switching between standard and low‑iron premium ATH: dedicated set of conductive brushes, scrapers and vacuum filters.
- Document cleaning log; take photos of classifier wheel and rotor after cleaning.
- For grade changeover, extend cleaning and do a short “run-in purge” with clean low‑contaminant ATH feed before sampling finished product.
5. Post-cleaning inspection & re-commissioning checklist
- Confirm all tools, scraps, and debris are removed from the mill cavity.
- Check that all purge air orifices, labyrinth seal passages and balance holes are clear.
- Verify all grounding bonds are reconnected and intact.
- Close all inspection doors, check gaskets for damage and tighten evenly to prevent air leakage.
- Remove LOTO tags only after all personnel are clear of the mill interior.
- Start with no load, run the classifier and rotor separately to check vibration; confirm no imbalance.
- Start at low feed rate, monitor temperature, PSD and current for 15–30 minutes before returning to full production.
6. Additional ATEX & static safety reminders
- All cleaning activity must be done in a well‑ventilated area; limit the number of workers inside the platform enclosure.
- If thick cake is found, investigate root cause: usually high feed moisture, low RH, poor static grounding or seal purge failure.
- Schedule cleaning frequency: for premium ultrafine ATH, visual inspection of classifier wheel every 200–400 operating hours; full internal clean every 800–1200 hours, or after each grade change.
The safest standard workflow for ACM mill internal cleaning: LOTO → cool down → atmosphere check → bonded conductive vacuum + low-pressure antistatic air purge (≤0.2 MPa) → non-ferrous scraper for hard cake → inspection and balance check → no-load vibration test. Avoid water and steel tools to protect both equipment safety and ATH product quality.