Aluminum hydroxide (ATH) is a heat‑sensitive flame‑retardant filler; it begins to release crystal water near 150 °C, which ruins whiteness, particle properties and halogen‑free flame‑retardant performance. Direct, reliable grinding‑chamber temperature monitoring is not a single‑sensor job. The best practice for ATH air classifier mill lines is a multi‑point PT100‑based contact sensing scheme,…

Aluminum hydroxide (ATH) is a heat‑sensitive flame‑retardant filler; it begins to release crystal water near 150 °C, which ruins whiteness, particle properties and halogen‑free flame‑retardant performance. Direct, reliable grinding‑chamber temperature monitoring is not a single‑sensor job. The best practice for ATH air classifier mill lines is a multi‑point PT100‑based contact sensing scheme, paired with air‑stream temperature tracking, PLC interlocks and periodic infrared hotspot verification, rather than relying only on surface IR guns.

Core sensor selection: PT100 RTD (preferred)

PT100 3‑wire platinum resistance sensors are the standard for ATH grinding chambers, with ±0.5 °C accuracy and good vibration and dust resistance. Thermocouples can be used as secondary backups, but they drift more easily in continuous ultrafine powder environments. Avoid non‑contact infrared sensors as your primary reading: IR only sees surface shell temperature and is skewed by powder coating, dust buildup and reflective mill housing. IR is excellent for spot hotspot checks, not continuous process control.

Recommended sensor placement (critical for ATH)

Install multiple probes to capture the high‑heat grinding zone, not just one wall point:

  1. Grinding rotor zone (primary point): Threaded penetration probe sealed with anti‑powder graphite packing, inserted into the grinding cavity near the impact/pulverizing area. This gives the closest reading to where ATH particles absorb friction heat. This is your main control point.
  2. Classifier wheel inlet zone: A second PT100 at the transition between grinding chamber and classifier. This spot shows trapped heat before powder enters classification; it is highly sensitive to choking, over‑feed or reduced airflow.
  3. Water‑jacket shell wall points: Surface‑mounted PT100s on the cooling jacket housing, to track jacket heat transfer and identify uneven cooling.
  4. Process air inlet and classifier outlet ducts: Measure carrier air temperature before it enters the mill and after classification. Air delta‑T tells you how much heat the grinding process is generating, independent of wall conduction.
  5. Bearing housings: Separate PT100s for rotor and classifier bearings; bearing friction is a frequent hidden heat source that can raise local chamber temperature.

For ATH lines, the target stable internal chamber temperature is kept well below 120 °C, with a conservative alarm threshold around 110 °C, long before the 150 °C dehydration threshold.

PLC closed‑loop interlock logic (the most valuable part for ATH safety)

Sensors connect to the mill PLC with 4–20 mA transmitters, and the temperature signal must be linked to the feeder, cooling water valve and exhaust fan — this is what turns monitoring into protection.

  • Temperature rising above warning setpoint: automatically reduce feeder frequency / lower feed rate (matches the anti‑choking adjustment workflow we covered earlier).
  • Temperature approaching critical limit: trigger alarm, further throttle feed, open chilled water control valve.
  • Temperature hitting trip setpoint: stop feeding first, keep exhaust fan running for purging; full mill stop if temperature continues climbing.
  • Log all temperature trends together with motor current, differential pressure and feed rate. Trend logs reveal slow drift from fouled classifier blades, clogged cooling jackets or changing raw ATH moisture.

Complementary monitoring methods

  1. Periodic infrared thermal scanning: Use an IR camera or handheld IR thermometer during routine rounds to scan the chamber outer shell, classifier housing and transition ducts. This finds hidden hot spots that embedded PT100 probes may miss, such as powder adhesion on internal walls. Do not use IR readings as the control signal.
  2. Product temperature spot checks: Take powder samples at cyclone or baghouse discharge for contact temperature measurement. This confirms whether the particle bulk temperature matches chamber air temperature; sticky, high‑moisture ATH can trap heat inside agglomerates even if air readings look normal.
  3. Heat balance cross‑check: Track inlet air temp, outlet air temp, airflow and motor power draw. A sudden jump in temperature rise per kWh often signals over‑feeding, poor airflow or incipient choking.

Common pitfalls to avoid for ATH mills

  • Single wall‑surface sensor only: shell temperature lags and underestimates internal particle temperature.
  • Over‑relying on IR: powder coating on the housing will make readings artificially low and give false confidence.
  • Poor sealing of penetration probes: ultrafine ATH powder leaks into the sensor port, builds up and insulates the probe, causing low and unstable readings.
  • No interlock: manual‑only watching fails during operator shifts; temperature drift from slow choking or filter blinding can sneak up and cause thermal degradation of ATH batches.

The best monitoring setup for ATH grinding chamber temperature:

Primary: multiple sealed PT100 penetration probes in grinding zone + classifier inlet, linked to PLC with automatic feed‑rate reduction and cooling control.

Secondary: inlet/outlet air temperature, bearing temperature, regular IR hotspot surveys and periodic product powder temperature verification. This layered method gives true internal process temperature, protects ATH crystal water and works hand‑in‑hand with your feed‑rate choking prevention strategy.

Written by
JACAN
Free Custom Process Solution
We specialize in dry ultrafine processing R&D and share practical technical insights for buyers worldwide. Contact us now to get your free tailored process proposal.
I Need Solutions
JACAN Powder Equipment

More Insights

Explore professional perspectives and technical breakthroughs in ultrafine grinding.

How To Design An Explosion-Proof ATH Grinding System

ATH (aluminum hydroxide) is generally considered low-risk compared with combustible organic powders, but ultrafine ATH…

How To Ensure Zero Emission In An Ath Surface Modification Plant

Zero emission for an ATH (aluminum hydroxide) surface modification plant means capturing all solid powder,…

How to Minimize Water Usage in Wet Grinding of ATH

Wet grinding of aluminum hydroxide (ATH) consumes water for slurry preparation, bead milling, classification, media…

What Is the Best Dust Collection System for an Aluminum Hydroxide (ATH) Processing Facility

The recommended standard solution for ATH grinding/classification lines is a two-stage dry system: cyclone pre-separator +…

Chat with us