All values are dB(A), measured at 1 m from the mill / circuit, under normal steady load, for a full closed ATH grinding system (mill + classifier + ducting + main ID fan). Fan noise is often the dominant source, not the grinding chamber itself.
Noise by mill type for ATH
- ACM Air Classifier Mill (the most common for ATH)
- Standard 5 t/h production line, without sound enclosure: 80–88 dB(A)
- Factory fitted acoustic housing / silencers: 72–78 dB(A)
- Main noise sources: high-speed rotor, classifier wheel, and the ID blower.
- Vertical Roller Mill (VRM)
- Standard enclosed VRM ATH circuit: 75–82 dB(A)
- Better than ACM because it uses bed compression instead of high-speed impact; vibration is lower.
- Ring Roller / Raymond mill
- Typical: 83–90 dB(A)
- Roller–ring mechanical impact and shovel blade vibration create more tonal noise.
- Fluidized Bed Jet Mill (FBJM)
- Mill body alone: 75–83 dB(A)
- Full system including high-pressure compressor room: 85–92 dB(A) (the air compressor is the big noise source here).
- Ball Mill closed circuit (dry)
- Uninsulated: 95–105 dB(A)
- With sound booth: 82–88 dB(A)
- This is the loudest common ATH grinding option, from cascading steel media impact.
Key factors that change the noise reading
- The induced draft fan is usually the loudest component in ACM/VRM ATH lines, not the grinding chamber. Poor fan silencing can push the whole system +5–8 dB(A).
- Finer ATH operation = higher airflow, higher fan speed → noise increases.
- Worn rotor pins, blades, loose foundation bolts, or imbalance raise vibration and noise.
- ATH feed with tramp quartz creates harsher impact and higher noise.
- Sound measurement location: operator walkway vs inside the steel platform enclosure will differ significantly.
Practical compliance context
Most occupational limits require action at 80 dB(A) and mandatory hearing protection above 85 dB(A). For ATH plants, the standard mitigation package includes:
- Fan inlet/outlet silencers
- Vibration isolation pads under mill and fan
- Acoustic enclosure for the ACM mill body
- Duct flexible connectors to stop structure-borne noise
Quick summary table
| Mill Type | Full System Noise (dB(A)) | Notes |
|---|---|---|
| ACM Air Classifier Mill | 80–88 (72–78 with enclosure) | Most common ATH line |
| VRM Vertical Roller Mill | 75–82 | Low mechanical impact |
| Ring Roller / Raymond | 83–90 | Higher mechanical impact noise |
| Fluidized Bed Jet Mill | 75–83 (mill only) | Compressor adds major noise |
| Dry Ball Mill | 95–105 (uninsulated) | Loudest, heavy impact noise |